NA2XY

تک رشته
Packing* Cable weight Insulation thickness External diameter Construction of individual conductor Construction number of cores x conductor cross-section Code No.
  .Nom .nom .Nom nominal      
  kg/km mm mm nx mm   Nx mm²  
CUT 85 0.7 8.4 7x 1.35 RM 1x10 A1110
CUT 115 0.7 9.4 7x 1.7 RM 1x 16 A1116
CUT 160 0.9 11.1 7x 2,2 RM 1x 25 A1125
CUT 200 0.9 11.7 7x 2,6 RM 1x 35 A1135
CUT 260 1 13.1 19x 1,8 RM 1x 50 A1150
CUT 340 1.1 15.1 19x 2,2 RM 1x 70 A1170
CUT 430 1.1 16.6 19x 2,6 RM 1x 95 A1195
CUT 500 1.2 17.3 19x 2,8 RM 1x 120 A11120
CUT 640 1.4 20.6 37x 2,3 RM 1x 150 A11150
CUT 790 1.6 22.5 37x 2,6 RM 1x 185 A1185
CUT 1,010 1.7 25.8 37x 2,95 RM 1x 240 A11240
CUT 1,210 1.8 27.9 61x 2,6 RM 1x 300 A11300
CUT 1,700 2 31.2 61x 2,89 RM 1x 400 A11400
CUT 1,990 2.2 34.8 61x 3,23 RM 1x 500 A11500
CUT 2,480 2.4 42.1 91x 2,97 RM 1x 630 A11630
               
دو رشته
Packing* Cable weight External diameter sheath  thickness Insulation thickness Construction number of cores x conductor cross-section Code No.
  .Nom .nom .Nom .nom      
  kg/km mm mm mm   Nx mm²  
CUT 350 16.2 1.8 0.7 RM 2x 10 A1210
CUT 460 18.7 1.8 0.7 RM 2x 16 A1216
CUT 590 22.1 1.8 0.9 RM 2x 25 A1225
CUT 740 23.3 1.8 0.9 RM 2x 35 A1235
CUT 840 20.9 1.8 1 SM 2x 50 A1250
CUT 1,100 23.8 1.8 1.1 SM 2x 70 A1270
CUT 1,440 27.2 2 1.1 SM 2x 95 A1295
CUT 1,740 30.2 2.1 1.2 SM 2x 120 A12120
CUT 2,040 33.4 2.2 1.4 SM 2x 150 A12150
CUT 2,600 36.8 2.3 1.6 SM 2x 185 A12185
CUT 3,215 41.5 2.5 1.7 SM 2x 240 A12240
CUT 3,950 46 2.7 1.8 SM 2x 300 A12300
               
سه رشته
Packing* Cable weight External diameter sheath  thickness Insulation thickness Construction number of cores x conductor cross-section Code No.
  .Nom .nom .Nom .nom      
  kg/km mm mm mm   N x mm²  
CUT 285 17 1.8 0.7 RM 3x 10 A1310
CUT 510 19.7 1.8 0.7 RM 3x 16 A1316
CUT 660 23.4 1.8 0.9 RM 3x 25 A1325
CUT 830 24.6 1.8 0.9 RM 3x 35 A1335
CUT 950 24.2 1.8 1 SM 3x 50 A1350
CUT 1,130 27.8 1.9 1.1 SM 3x 70 A1370
CUT 1,430 31 2 1.1 SM 3x 95 A1395
CUT 1,720 34.3 2.1 1.2 SM 3x 120 A13120
CUT 2,115 38.4 2.3 1.4 SM 3x 150 A13150
CUT 2,580 42.5 2.4 1.6 SM 3x 185 A13185
CUT 3,280 47.5 2.6 1.7 SM 3x 240 A13240
CUT 3,970 49.5 2.8 1.8 SM 3x 300 A13300
               
چهار رشته
Packing* Cable weight External diameter sheath  thickness Insulation thickness Construction Dimensions – number of cores x conductor cross-section Code No.
  .Nom .nom .Nom .nom      
  kg/km mm mm mm   N x mm²  
CUT 650  24.5 1.8 0.9 RM/RM 3x 25/16 A14325/16
CUT 850  26 1.8 0.9 RM/RM 3x 35/16 A14335/16
CUT  950 25.7 1.8 1 Sm/RM 3x 50/25 A14350/25
CUT  1330 29.4 1.9 1.1 SM/RM 3x 70 /35 A14370/35
CUT  1750 33.1 2.1 1.1 SM/SM 3x 95 /50 A14395/50
CUT  2100 36.7 2.2 1.2 SM/SM 3x 120 /70 A143120/70
CUT 2600  40.9 2.3 1.4 SM/SM 3x 150/70 A143150/70
CUT  3200 45.4 2.5 1.6 SM/SM 3x 185/95 A143185/95
CUT  4050 50.8 2.7 1.7 SM/SM 3x 240/120  A143240/120
CUT  4750 56 2.8 1.8 SM/SM 3x 300/150 A143300/150
CUT 450 18.4 1.8 0.7 RM 4X 10 A1410
CUT 605 21.4 1.8 0.7 RM 4X 16 A1416
CUT 790 25.5 1.8 0.9 RM 4X 25 A1425
CUT 995 26.9 1.8 0.9 RM 4X 35 A1435
CUT 1,060 27 1.9 1 SM 4X 50 A1450
CUT 1,435 30.9 2 1.1 SM 4X 70 A1470
CUT 1,820 34.5 2.1 1.1 SM 4X 95 A1495
CUT 2,275 38.5 2.3 1.2 SM 4X 120 A14120
CUT 2,750 42.9 2.4 1.4 SM 4X 150 A14150
CUT 3,340 47.6 2.6 1.6 SM 4X 185 A14185
CUT 4,250 53.2 2.8 1.7 SM 4X 240 A14240
CUT 5,135 58.9 3 1.8 SM 4X 300 A14300
               
پنج رشته
Packing* Cable weight External diameter sheath  thickness Insulation thickness Construction Dimensions – number of cores x conductor cross-section .Code No
  .Nom .nom .Nom .nom      
  kg/km mm mm mm   N x mm²  
CUT 525 20 1.8 0.7 RM 5X 10 A1510
CUT 710 23.3 1.8 0.7 RM 5X 16 A1516
CUT 935 27.9 1.8 0.9 RM 5X 25 A1525
CUT 1,190 29.5 1.8 0.9 RM 5X 35 A1535
CUT 1,480 34 2 1 RM 5X 50 A1550
دمای حین نصب 5°C up to +50°C-
دمای نصب ثابت 20°C up to +90°C-
دمای اتصال کوتاه up to 250°C
ولتاژ کاری Uο/U = 0,6/1 kV
ولتاژ تست 3.5 kV AC
ماکزیموم ولتاژ کاری در سیستم 3 فاز 1,2 kV
حداکثر مقاومت کششی 30 N/mm²
رفتار در برابر آتش IEC 60332-1
حداقل شعاع خمش  
تک رشته 15D
چند رشته 12D

 

Conductor Inductance Current - Carrying Capacity at 30° C * Short circuit current at 1 sec
Nom. Cross Section Area DC Resistance at 20°C AC Resistance at 90°C
in air in ground
(mm²) Max. (Ω/km) Max. (Ω/km) (mH/km) Max. (A) Max. (A) Max. (kA)
10 3.08 3.949 0.248 67 75 0.94
16 1.91 2.449 0.236 91 100 1.5
25 1.2 1.539 0.242 119 128 2.35
35 0.868 1.113 0.234 147 154 3.29
50 0.641 0.822 0.232 179 183 4.7
70 0.443 0.568 0.229 227 226 6.58
95 0.32 0.411 0.224 277 270 8.93
120 0.253 0.325 0.223 322 308 11.28
150 0.206 0.265 0.225 364 344 14.1
185 0.164 0.211 0.225 425 391 17.39
240 0.125 0.162 0.223 501 454 22.56
300 0.1 0.13 0.222 574 511 28.2
هادی : مفتول آلومینیوم کلاس 1 یا 2 مطابق استاندراد IEC 60228
کلاس1 : مفتول (RE)
کلاس 2 مفتول استرند شده (RM) فشرده شده  یا سکتور (SM) برای مقاطع بالای 50 میلیمتر مربع
عایق: کامپاند XLPE
فیلر: کامپاند PVC
روکش: PVC ST1 مطابق با   IEC 60502-1
رنگ روکش: مشکی
Izvedba.jpg

 از این کابل جهت انتقال قدرت و یا ارسال سیگنال در زیر زمین، آب، بین کارگاه ها، در کنار کانال ها در بتن و در شرایطی که احتمال وقوع صدمه مکانیکی است استفاده می شود. هادی های هم محور می توانند به عنوان محافظ یا اتصال به زمین عمل کنند. در شرایط که احتمال صدمه ناشی از کندن زمین و خرابی عایق اصلی وجود دارد این هادی را به عنوان محافظت کننده در مقابل جریان اتصال کوتاه عمل می کنند.

 در پست های برق، کارخانجات صنعتی، شبکه زیر ساخت شهری و نیرو گاهها جایی که نیاز به عبور جریان بالا و تحمل دما مد نظر باشد ( عملکرد تا دمای ۹۰ درجه سانتیگراد) از این کابل استفاده می شود.