NYMHY

12, 13, 16
درباره:

از اين نوع کابل‌ها به عنوان کابل‌هاي رابط جهت استفاده در وسايل الکتريکي، لوازم خانگي و ماشين آلات استفاده می شود . تماس مستقيم کابل با قسمت‌هاي داغ در وسايل پخت و پز و گرمايشي مجاز نمي‌باشد و کابل نبايد در معرض گرما قرار گيرد

Flame Retardant Acc to IEC60332-1-2, Flexible, Max cinductor temperature 70

specs

کابلهای ساختمانی
Electrical Specs:
300/500V(Generally as IEC 60227)
.Code No number of cores x conductor cross-section Construction of individual conductor External diameter Insulation thickness Sheath thickness Conductor resistance at 20 °C Cable weight Packing**
nominal min-max. nominal nominal max. approx.
  mm² n x mm mm mm mm Ω/km kg/km  
13275 2x 0.75 24x 0.195 5.7-7.2 0.6 0.8 26 52 c.100
13210 2x 1.0 31x 0.195 5.9-7.5 0.6 0.8 19.5 65 c.100
13215 2x 1.5 31x 0.23 6.8-8.6 0.7 0.8 13.3 90 c.100
13225 2x 2.5 51x 0.23 8.4-10.6 0.8 1 7.98 115 c.100
13240 2x 4 83x0.23 10.2-10.6 0.8 1 4.95 183 c.100
13260 2x 6 82x0.28 11.6-12.0 0.8 1.1 3.3 258 c.100
132100 2x10 70x0.395 15.4-15.8 1 1.2 1.91 442 c.100
132160 2x16 118x0.395 18.2-18.6 1 1.6 1.21 696 CUT
132250 2x25 186x0.395 22.2-22.6 1.2 1.8 0.78 965 CUT
13375 3x 0.75 24x 0.195 6.0-7.6 0.6 0.8 26 70 c.100
13310 3x 1.0 31x 0.195 6.3-8.0 0.6 0.8 19.5 80 c.100
13315 3x 1.5 31x 0.23 7.4-9.4 0.7 0.9 13.3 115 c.100
13325 3x 2.5 51x 0.23 9.2-11.4 0.8 1.1 7.98 175 c.100
13340 3x 4 83x0.23 10.5-13.4 0.8 1.2 4.95 234 c.100
13360 3x 6 82x0.28 12.5-12.9 0.8 1.2 3.3 321 c.100
133100 3x10 70x0.395 17.0-17.4 1 1.5 1.91 585 c.100
133160 3x16 118x0.395 19.4-19.6 1 1.6 1.21 811 CUT
133250 3x25 186x0.395 23.6-24.0 1.2 1.8 0.78 1238 CUT
13475 4x 0.75 24x 0.195 6.6-8.3 0.6 0.8 26 75 c.100
13410 4x 1.0 31x 0.195 7.1-9.0 0.6 0.9 19.5 92 c.100
13415 4x 1.5 31x 0.23 8.4-10.5 0.7 1 13.3 145 c.100
13425 4x 2.5 51x 0.23 10.1-12.5 0.8 1.1 7.98 210 c.100
13440 4x 4 83x0.23 12.3-12.7 0.8 1.2 4.95 296 c.100
13460 4x 6 82x 0.28 14.7-15.0 0.8 1.2 3.3 480 c.100
134100 4x10 70x0.395 19.3-19.7 1 1.8 1.91 755 CUT
134160 4x16 118x0.395 21.7-22.1 1 1.8 1.21 998 CUT
134250 4x25 186x0.395 26.7-27.1 1.2 2.1 0.78 1586 CUT
13575 5x 0.75 24x 0.195 7.4-9.3 0.6 0.9 26 96 c.100
13510 5x 1.0 31x 0.195 7.8-9.8 0.6 0.9 19.5 113 c.100
13515 5x 1.5 31x 0.23 9.3-11.6 0.7 1.1 13.3 175 c.100
13525 5x 2.5 51x 0.23 11.2-13.9 0.8 1.2 7.98 260 c.100
13540 5x 4 83x0.23 16.1-16.7 0.8 1.4 4.95 363 c.100
13560 5x 6 82x 0.28 16.7-16.9 0.8 1.5 3.3 585 c.100
135100 5x10 70x0.395 21.2-21.6 1 1.8 1.91 934 CUT
135160 5x16 118x0.395 24.0-24.4 1 1.8 1.21 1285 CUT
135250 5x25 186x0.395 29.4-29.8 1.2 2.1 0.78 1976 CUT
*)Packing: c.100 = coil 100 m, CUT= cable in different lengths on drum or reel, possible cutting at required 
Physical Specs:
Conductor: bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: PVC compound TI2 acc. to DIN VDE 0207 part 4/ HD 21.1 S4, concentrically stranded cores color marked acc. to HRN HD 308 S2 / DIN VDE 0293-308, with or without yellow-green protective conductor
Sheath: PVC compound TM2 for flexible cables acc. to DIN VDE 0207 part 5 / HD 21.1 S4
sheath color: white or black(Ral 9005)
Core color marking: HRN HD 308 S2 / VDE 0293-308
Technical Specs:
Temperature during installationi: +5 °C up to +70 °C
fixed installed Temperature: -30 °C up to +70 °C
Temperature at short circuit of max. 5 s: up to 150 °C
ambient temperature at storage: up to 40 °C
Nominal voltage: Uο/U = 300/500 V
Test voltage: 2000 V
Minimal inner bending radius: 4D for D < 8 mm 
5D for 8 - 12 mm 
6D for D > 12 mm
Behaviour in fire: IEC 60332-1